Version |
Picture |
Feature |
View |
WM-01/WM-02 Power Analyzer Datalogger |
|
4 LCD Displays with W, PF, V, A Easy Plug-in and Test RS-232 Computer Interface
|
|
TES-1380 PH / ORP / Temperature Meter |
|
Fast and Easy pH measurement Dual LCD display shows PH/℃& ℉ or mV/ ℃&℉ simultaneously Logging 99 readings
|
|
AVM-301/AVM-303 Anemometer |
|
AVM-301 AVM-303(RS232)PROVA-300XPProtable Thermal Printer Velocity (m/s, ft/min, knots, km/hr, mph) Fonctions Max / Min / Moyenne et Hold Ergonomic Design 0.3~45m/s range
|
|
AVM-05/AVM-07 Flow Anemometer |
|
Flow(CFM,CMM) Instant, Ave, 2/3max Flow Measurement Velocity m/s, ft/min, knots,Km/hr, mph LCD Dual Display ℃ / ℉
|
|
AVM-01/AVM-03 Anemometer |
|
Sensitive for low/high air velocity Ergonomic Design 0.3~45m/s range
|
|
TES-1800 LOOP / PSC Tester |
|
TES-1800A (230V) TES-1800B (110V) Large custom high contrast display. Auto lock out if test resister overheats. Voltage indication. Measure low loop with 0.01 W resolution. High loop range permit measurement of ground spikes. Microprocessor controlled.
|
|
TES-1339 Light Meter Pro. |
|
Dual Display, 4-digit LCD reading. Spectral Sensitivity close to CIE photopic Curve. Measuring Levels Ranging 0.01 to 999900 Lux,0.01 to 99990 fc, Autoranging 5 step. Accurate and Instant response. Integral illuminance measurement. Luminous intensity measurement. Data Hold function. Data memory and read function. Reference value setting for relative or percentage deviation measurement. Ripple measurement for STRAY + LIGHT function. Time-hold function. Point - average function. Comparator function. Auto power off function. CNS 5119 Class Ⅱ .
|
|
TES-1336A Datalogging Light Meter (RS-232) |
|
Spectrum of photo sensor meets C.I.E. photopic curve V( l ) 16000 Records Data logging capacity RS-232 interface (software included) Measurement of luminous intensity (PC Software)
|
|
TES-1335 Digital Light Meter |
|
Spectral Sensitivity close to CIE photopic Curve. Measuring Levels Ranging 0 to 400,000 Lux, 0 to 40, 000 fc. Accurate and Instant response. Data Hold function. MAX/MIN function. Peak Hold function. Relative function. Cosine Angular corrected. Auto-Power-Off function. CNS 5119 class11
|
|
TES-1330A/TES-1332A/TES-1334A Light Meter |
|
Spectral Sensitivity close to CIE photo pic Curve Cosine Angular corrected Analog output jack for recording (TES-1332A/1334A) Data Hold function, Peak Hold function for 1334
|
|
TES- 1370 NDIR CO 2 METER |
|
CO 2 : 0 ~ 6,000 ppm range, Diffusion sampling mode. Three LCD Display for CO 2 , %RH Humidity and Air Temperature. Maintenance free dual wavelength NDIR infrared CO 2 sensor (non-dispersive infrared). Continuous or manual data logging (20,000 sets). Data hold & Maximum / Minimum with Time stamp. Data Memory and READ function. Alarm and Time setting. RS-232 function / Software. Backlight display function. Simple and safe to use.
|
|
TES-32 Battery Capacity Tester (RS-232) |
|
Test Condition Without Shutting Down Battery. Simultaneously Measure Battery Resistance, Voltage. Comparator Function. Rates Conditions as Pass, Warning, or Fail. Memory and Read Function Compact and Lightweight. RS232 PC Interface
|
|
TES-46A CAT-5 Lan Cable Tester |
|
Tests : UTP. FTP. Coax cables, two, three, or four wire pairs in twisted pair cables and test all category UTP cables and hardware. Verify end-to-end connectivity per EIA/TIA 568 wiring standard. Detects wiring problems : Opens, Shorts, miswires (Crossed, Reversed, Split pair). Locates wiring/connection errors (distance to the open or shout) Measures cable length Easy to use only : One button to select the test and two lines characters LCD display. Low battery, Auto power off, long battery life (60 hours continuous)
|
|
TES-45A CAT-5 Lan Cable Tester |
|
Test a wide range of UTP cables such as 10Base T , 100Base Tx , 10Base 2 (Coax), 356A , TIA-568A , TIA-568B, etc. Can tests for wiring faults such as open, short , reversed , crossed and split wires. Can identify up to 4 different cables at one end by provided remote identifiers. Double digital 14-segment LED and 4 pair LEDs clearly display the fault status. Provided over voltage (max.56V) protection to prevent damage frommiss connecting to live circuit of networking. Simple and effective use. Auto power off
|
|
TES-3660 Autoranging Insulation Tester |
|
Large LCD with analog bar graph and digital display. 250V, 500V, 1000V output voltage for insulation M Ω testing. 4000M Ω insulation testing with automatically switch to voltage measurement. Lo Ω function for testing connections. Autodischarge of capacitive voltage charges. Last reading HOLD display. AC/DC voltage measurement up to 1000V. Manual data memory and read function (9 sets). Meets EN61557 and IEC1010-1, CAT III 1000V. Size : 235(L)x116(W)x54(H)mm (9.3"Lx4.6"Wx2.1"H)
|
|
TES-1604 AUTORANGING INSULATION TESTER |
|
Innovational logging feature (7000) to memorize all of measurements from the work place RS-232 interface with valued software 4,000M W /V Reding/10,000M W analog indication Backlight illumination 3-3/4 Digital LCD, 4000Count Auto Range for Mega Ohm range 50 segments Log Scaled Analog Display Easy to carry testing package Tests insulation at rated voltage into a 1mA load 200mA short circuit continuity current Meet VED0413 Auto discharge
CAT II pollution 2 1000V CAT III pollution 2 600V
|
|
TES-1601 Auto Ranging Insulation Tester |
|
4000M W /1000V, 4000M W /500V, 4000M W /250V Power lock for 3 minutes (Auto power off) Auto-Zero adjustment Data-Hold-Function
|
|
TES-1600 Insulation Tester |
|
2000M W /1000V, 200M W /500V, 200M W /250V Power lock for 3 minutes (Auto power off) Auto-Zero adjustment Data-Hold-Function
|
|
TES-1364/TES-1365 Datalogging Humidity Temperature Meter |
|
Detachable sensing probe. Data Hold & Relative function. Dual LCD display with Bargraph indication. Datalogging capacity 10,100 dual reading. (%RH & Temp). (TES-1365) Dew Point Reading. RS-232 interface & windows software. (TES-1365) Wet bulb Reading. Automatic Timer Recording for Datalogger. (TES-1365) MAX/MIN with Time Stamp.
|
|
TES-1362 Printing Humidity Temperature Meter |
|
Triple LCD Display for RH% Humidity, T1 for Air Temperature and T2 Type K Thermometer (-200 ℃ ~ 1333 ℃ ). Dew Point Reading. Max / Min / Data Hold. Real Time Stamp. Periodically Print out from Pre-Set time Interval
|
|
TES-1361C Datalogging Humidity/Temperature Meter |
|
Instant preformance of Humidity measurement by precision thin-film capacity sensor Dual display LCD / Clock Compact, light weight & Simple operation 7000 Record Data logging Capacity (Dual Reading) RS-232 interface (software included)
|
|
TES-1360A Humidity/Temperature Meter |
|
Laboratory Quality Control Air-Conditioning Process Engineering
|
|
TES-92 ElectroSmog Meter |
|
50 MHz to 3.5 GHz frequency range. For isotropic measurements of electromagnetic fields. Non-directional (isotropic ) measurement with three-channel measurement probe. High dynamic range due to three-channel digital results processing. Configurable alarm threshold and memory function. Easy to use
|
|
TES-1393/TES-1394 ElectroMagnetic Field Tester (W/RS-232) |
|
The EMF tester is designed to provide user a quick, reliable and easy way to measure electromagnetic field radiation levels around power lines, home appliances and industrial devices. The EMF tester is a cost effective, hand-held instrument designed and calibrated to measure electromagnetic field radiation at different bandwidths down to 50Hz/60Hz. Display micro Tesla & milli Gauss in the same tester. Data hold, Peak hold function. RS-232 Optical inter face. (1394) 999 Datalogging capacity.
APPLICTIONS This EMF tester is specifically designed to determine the magnitude of electromagnetic filed radiation generated by power lines, computer's monitor, TV sets, video machinery and many other similar devices.
|
|
TES-1390/TES-1391/TES-1392 EMF TesterElectroMagnetic Field Tester |
|
The EMF tester is designed to provide user a quick, reliable and easy way to measure electromagnetic field radiation levels around power lines, home appliances and industrial devices. The EMF tester is a cost effective, hand-held instrument designed and calibrated to measure electromagnetic field radiation at different bandwidths. Display micro Tesla & milli Gauss in the same tester. Data hold, Peak hold function On-line computer (1391/1392) Data logging (1392) function.
|
|
TES-1356 Sound-Level Calibrator |
|
94dB and 114dB Sound Calibration at 1KHz Accurate and Simple to use Fits 1", 1/2" or 1/4" diameter microphone
|
|
PROVA-123 Process Calibrator |
|
4-20mA, 0-20mA, 0-24mA with 1 m A resolution 0-100mV with 10 m V resolution 0-12V with 1mV resolution Thermocouple K,J,E,T TYPE 1 o C 1 o F resolution Frequency 2 - 50,000Hz
|
|
PROVA-125 Temperature Calibrator |
|
Simple & Easy to key-in the exact temperature value you need Dual LCD display to show the Reference Room Temperature at the same time Accept 11 different type of Thermocouple (K, J, E, T, R, S, N, L, U, B, C) Auto-Ramp & T function
|
|
PROVA-100 4-20mA LOOP CALIBRATOR |
|
4-20mA, with 1 m A resolution Basic Accuracy 0.025% + 5 m A Auto-Ramp and Easy Step Functions 1-100% Input 0-20mA, 0-24mA Selectable Easy Just-Type-in Number Operation
|
|
TES-1605 Digital Earth Tester |
|
Capable of measuring earth voltage. Data hold function. Auto power off function: The timer operates automatically about 3 minutes when the " Test Button Switch " are pressed to keep the tester power on. 2mA measuring current permits earth resistance tests without tripping earth leakage current breakers in the circuit under test. In addition to the facility for precision measurement, test leads for simplified two wire measuring system also supplied as standard accessories. Automatic warning when resistance of auxiliary earth spike is in excess of tolerance. Designed to meet IEC1010-1 safety standard. Zero ohm adjustment.
|
|
TES-1700 Digital Earth Tester |
|
Capable of measuring earth voltage. Data hold , MAX / MIN function. Auto power off function: The timer operates automatically about 3 minutes when the " Test Button Switch " are pressed to keep the tester power on. 2mA measuring current permits earth resistance tests without tripping earth leakage current breakers in the circuit under test. In addition to the facility for precision measurement, test leads for simplified two wire measuring system also supplied as standard accessories.(unit can be hung from the neck for simplified measurement). Automatic warning when resistance of auxiliary earth. Spikes is in excess of tolerance. Designed to meet IEC1010-1 safety standard.
|
|
PROVA-5601/PROVA-5637 Clamp-on Ground Resistance Tester |
|
Non-Contact Ground Resistance Measurement No Auxiliary Electrode Needed Jaw Diameter Φ 23 mm (5601) Jaw Diameter Φ 35 mm(5637) 0.025 – 1500 Ohm 0.2mA– 30A(5601)0.2mA– 35A(5637),True RMS 116 Sets of Memory(5601,5637) Programmable Hi and Lo Alarm(5601,5637) Programmable Data Logging (5601,5637) APPLICTIONS Telecommunication Cable TV system Electrical Power Plant Cellular Phone System Factory and Facility Gas Station Tank
|
|
TES-3092 DC/AC CLAMP METER |
|
3-1/2 Digital LCD, 2000 count. Pocket size. MAX hold / Data hold function. One touch DCA zero
|
|
TES-3091R DC/AC CLAMP METER |
|
3-1/2 Digital LCD, 2000 count. Pocket size. MAX hold / Data hold function
|
|
TES-3082 True RMS Clamp Meter |
|
EN61010-1 600V INSTALLATION VAT III POLLUTION DEGREE2
Auto-Ranging Frequency measurements Auto ZERO mode Data Hold mode PEAK Hold mode True RMS Reading
|
|
TES-3079 HVAC Trms Clamp Meter (1000A) |
|
HVAC Application Check current draw in motors and compressors. Use MAX/MIN/Recording in the temperature mode to assess efficiency. Test run/start capacitors. Confirm low voltage control signals. Measure flame safeguard device current draw. Confirm power sources Analyze temperature and power data with the aid of the time stamp. Insulation test up to 100M. Electrical Application Check for energized circuits. Balance loads. Evaluate electrical contacts. Capture motor in-rush current readings. Determine peak power demand periods. Verify line voltage stability. Monitor motors and other loads for excess heat. Check motor run/start capacitor values
|
|
TES-3074 AC 1000A Clamp Meter |
|
Capacitance Measurement (400μF). MAX / MIN / Data Hold. Phase Rotation Indicator. Pos Peak Hold & Neg Peak Hold. 1000A AC & 600V AC
|
|
TES-3050 TRMS AC/DC Clamp Meter |
|
EN61010-1 600V INSTALLATION VAT III POLLUTION DEGREE 2
3-3/4 Digital LCD with bar-graph Auto-ranging off / Data Hold / Peak Hold / MAX/MIN mode Zero Adjustment/Relative Reading
|
|
TES-3040 AC Clamp Meter |
|
EN61010-1 600V INSTALLATION VAT III POLLUTION DEGREE 2
3-3/4 Digital LCD with bar-graph Auto-power off with Data Hold and MAX/MIN mode Zero Adjustment/Relative Reading
|
|
TES-3010/3012 Prof. Clamp Meter |
|
ACA: 20A, 200A, 600A Continuity Buzzer Unit & Sign Display
|
|
PROVA-2009 AC/DC True RMS Watt Clamp |
|
AC+DC 1200KW DC/AC 2000A & ANALOG OUTPUT Cable F 55mm True RMS Temperature ( ℃ or ℉ ) 0.1 ℃ / ℉ Resolution
|
|
PROVA-2000/2003 Clamp Meter |
|
DC/AC 2000A Cable f 55mm, Bus Bar 72mm(D) x 22mm(W) True RMS (2000) Average Sensing (2003) DCA One Touch Zero Auto Range A, V, W Continuity Max/Min/Hold Relative Measurement
|
|
PROVA-15 AC/DC mA Current Probe |
|
High Resolution DC 1mA, AC 0.1mA Connect to an Oscilloscopes to observe Current Waceform Connect to Chart Recorder/Datalogger/ DMM to Record Current Data
|
|
PROVA-11 AC/DC mA True RMS Clamp Meter |
|
Super High Resolution DC 1mA, AC 0.1mA One Touch Zero for DCA True RMS
|
|
cm-07 TRMS DC/AC Clamp Meter |
|
High Resolution DC 10mA, AC 1mA True RMS Non-contact Current Frequency Measurement
|
|
cm-05 DC/AC Current Probe |
|
Accurate and High Resolution 23 mm Conductor Diameter One Touch Zero
|
|
cm-03 Leakage Current Tester |
|
10 m A Ultra High Resolution Large Conductor Diameter (30mm) ACA 5 Ranges (40mA, 400mA, 4A, 40A, 100A
|
|
cm-02/04 Clamp Meter/Automotive Clamp |
|
DC/AC 0.01A Resolution AC/DC 0.01A~200A 23mm Jaw Diameter One Touch Zero Temperature and Capcitance Auto Range V、 W 、Hz、 o C、 3 3/4 Digits (4000 Counts) 0~9999 RPM(CM-04)
|
|
CM-01 DC/AC Clamp Meter |
|
High Resolution DC/AC 10mA 23 mm Large Jaw Diameter One Touch Zero for DCA adjustment
|
|
PROVA-901/PROVA-903 Digital Multi-Meter |
|
The DMM to replace your bench-top one
0.02% DC and 0.1% AC basic accuracy 60,000 counts resolution 200KHz (max.) bandwidth True RMS with fast ACV/ACA response Dual channels measurement similar to a dual channels DSO (V+V, V+A) RS-232C ASCII interface Data logging (model 903 with 10,708 records for both channels) Capacitance measurement Free software (901,903) 1/3 the cost
|
|