Version |
Picture |
Feature |
View |
Luminous flux meter the TES-133 |
|
4-digit LCD display the best measurement of the spectral response ≦ 6% automatic transmission function from the accurate and quick response of 0.05 to 7000 lumens reading lock data memory and read function to zero the function of the ratio of the value of functional classification selection function of the photopic function : light emitting diode, light bulb, fiber optic lighting, automatic shutdown feature RS232 interface using a simple test baffle: 2/3/4/5/8/10m/m
|
|
Identify analysis instrument |
|
Check two objects sample the color difference between color differences Δ (L *, a *, b *) Δ (E * ab, C * ab, H * ab) Δ (Y, x, y) Δ (X, Y , Z) or Δ (Rs, Gs, Bs) color space (L *, a *, b *) (* in C * ab, hab) (Y-, x, y) (X, Y, Z) or (Rs, Gs, Bs) the maximum, minimum and mean value function to allow the error to set the automatic memory function (99), and read features mini-USB PC interface
|
|
TES-1333/TES-1333R Solar Power Mete |
|
Wide spectral range. Excellent long term stability. Cosine corrected. Automatic transmission measurements. Select either power or transmission. Solar energy power or transmission. Current time setting function. User calibration factor setting function. End-mount light sensor. Select either W/m2 or Btu / (ft2*h) units Data Hold / MAX / AVG modes. Data Memory and Read function. (99 sets.) Auto Data memory and RS232 interface to PC. (TES-1333R) APPLICATIONS Meteorology agriculture solar radiation measurement solar power research physics and optical laboratories solar transmission measurement identify high performancewindows
|
|
TES-1333/TES-1333R Solar Power Mete |
|
Wide spectral range. Excellent long term stability. Cosine corrected. Automatic transmission measurements. Select either power or transmission. Solar energy power or transmission. Current time setting function. User calibration factor setting function. End-mount light sensor. Select either W/m2 or Btu / (ft2*h) units Data Hold / MAX / AVG modes. Data Memory and Read function. (99 sets.) Auto Data memory and RS232 interface to PC. (TES-1333R) APPLICATIONS Meteorology agriculture solar radiation measurement solar power research physics and optical laboratories solar transmission measurement identify high performancewindows
|
|
PROVA-300XP Protable Thermal Printer |
|
Protable Field Printing for Certificate Text and Graphics Two Selectable Fonts (5*7 and 8*16) Programmable text Header and Footer Battery and AC Power Apaptor RS-232C Interface (Optional RS-232C to USB Bridge) Fized Interval Continuous Printing(5,30,60,300 seconds)
|
|
AFLEX-6300 Graphic Power Quality Analyzer |
|
Display of Overlapped Voltage and Current Waveform Maximum Demand(MD in W,KW,MW) with Programable Period Harmonics Analysis ( V and I ) to the 50th Order Display of 25 Harmonics in One Screen with Waveform Display of waveform with Peak Values (512 Samples / Period), Datalogging of 32, 64, 128 or 256 Points/Cycles Analysis of Total Harmonics Distortion ( % THD-F ) Graphic Phasor Diagram Programmable PT (1 to 3000) Ratios Capture 128 Transient Events ( Time + Cycles + Faults ) with Programmable Threshold(%), Can Also be Reviewed in LCD 50000 Records with Programmable Lnterval ( 1 to 6000 seconds) Output of Waveform, Power Parameters and 50 Harmonics at Command. Large Dot Matrix LCD Display with Backlight Optical Isolated RS-232C Interface Smart Datalogging to save Battery Power for Long-term Monitoring Built - in Calendar Clock for Data Logging
|
|
AFLEX-3003 Flexible VA Harmonics Tester |
|
Power Analysis(3005)
W, KW, H.P. VA ,KVA, VAR, KVAR PF, Phase Angle( Φ ) Energy (WH, KWH) Dual displays (W+PF, VA+KVAR) Balanced 3 Φ Power Quality and Swquence Harmonics Analysis
True RMS( V and A) 3000 A Non-interrupted Harmonic Analysis ( V and A ) to the 50th Order in % and Magnitude Analysis of % THD-F and C.F. Fast Peak Function (33μs and 39μs) Programmable PT (1 to 250 )ratios Auto - Power - Off:30 Minutes Flexible probe , different from normal clamp meter, can pass through obstacles at will and wind many conducting wires simultaneously, max. diameter 170mm
|
|
AFLEX-3001/3002 Flexible AC Current Clamp |
|
True RMS 3000A Voltage Measurement(AFLEX 3002 only) Fast Peak Function(30 μs) MAX/MIN Auto-Power-Off:30 minutes Flexible probe, diffent from normal clamp meter, can pass through obstacles at will and wind many conductiog wires simultaneously,max.diameter 170mm
|
|
AFLEX-3000 Flexible AC Current Probe |
|
Two Current Ranges:300A and 3000A Two Output Sensitivity(300 mV and 1V), Versatile for Measuring Instrumets Input Protection UP to 600V Suitable for Any Electrical System Wide Bandwidth , Low Phase Shift Low Battery Indication
|
|
PROVA-6200 Graphic Power Quality Analyzer |
|
Analysis for Single Phase and Balanced 3 phase system True RMS Value(V and I) Active Power(K,KW,MW,GW) Apparent(VA,KVA,MVA) and Reactive Power (VAR,KVAR,MVAR) Power Factor(PF),Phase Angle( Φ ) Energy(WH,KWH,KVARH,PFH) Programmable PT(1 to 3000)Ratios Display of Overlapped Voltage and Current Waveform Maximum Demand (MD in W,KW,MW)with programmable Period Harmonic Analysis (V and I) to 50th Order Display of 25 Harmonics in one screen Optical Isolated RS-232C Interface Smart Datalogging to save Battery Datalogging of 32,64,128 or 256 points/cycles Analysis of Tatal Harmonic Distortion(%THD-F) Graphic Phasor Diagram Capture 128 Transient Events(Time+Cycles+Faults) with Programmable Threshold(%),also can be reviewed in LCD 50000 Records with Programmable Intervel (1 to 6000 seconds) Real-time Output of Wavaform,Power Parameters and Harmonics at Command Large Dot Matrix LCD Display with Backlight Power for Long-term Monitoring Built -in Calendar Clock for Data Logging
|
|
PROVA-21/PROVA-23 Power Harmonics and Leakage Tester |
|
MODEL PROVA 19, 21, 23
True RMS value (V and A) Leakage Current Measurement at 10 μ A Resolution Harmonic Analysis (V and A) to the 99 th Order Better Understanding of High Frequency Harmonic Analysis (up to 5/6 KHz) Non-interrupted Harmonic Analysis Analysis of Total Harmonic Distortion (THD-F) Analysis of Crest Factor (C.F.) Fast Peak Function (33 μ s and 39 μ s) Programmable CT Ratio (1 to 250) Model 21(50A) and 23(100A)
W, KW, H.P. VA, KVA, VAR, KVAR PF, Phase Angle ( Φ ) Energy (mWH, WH, KWH) Analysis of Standby Power Consumption Balanced 3 Φ Power Quality B
|
|
PROVA-6830+6801 Power and Harmonics Analyzer (100A) |
|
Analysis for 3P4W, 3P3W, 1P2W, 1P3W True RMS Value(V 123 and L 123 ) Active Power(W, KW, MW, GW) Apparent and Reactive Power (KVA, KVAR) Power Factor (PF), Phase Angle (Φ) Energy (WH, KWH, KVARH, PFH) Current Measurement from 0.1mA to 3000A, Capable of Analyzing IT Standby Power Consumption to the Maximum Demand of a Factory Display of 35 Parameters in One Screen(3P4W) rogrammable CT (1 to 600) and PT (1 to 3000) Ratios Display of Overlapped Voltage and Current Waveform 2.4M Memory with Programmable Interval (1 to 6000 seconds, 17000 Records for 3P4W System) Output of Waveform, Power Parameters and Harmonics at Command Large Dot Matrix LCD Display with Backlight Average Demand (AD in W, KW, MW) aximum Demand (MD in W, KW, MW) with Programmable Period Harmonic Analysis to the 99th Order Display of 50 Harmonics in One Screen with Waveform Display of Waveform with Peak Values (1024 Samples/Period) Analysis of Total Harmonic Distortion (%THD-F) Graphic Phasor Diagram with 3 Phase System Parameters Capture 28 Transient Events (Time+Cycles) with Programmable Threshold(%) 3 Phase Voltage Unbalance Ratio (VUR) 3 Phase Voltage Unbalance Factor (d0%, d2%) Calculated Unbalance Current through Neutral Line (In) Optical isolated USB Interface Built-in Timer and Calendar for Data Logging onductor Size: -Model 6801 30mm(approx) -Model 6802 5 55mm(approx),64*24mm(bus bar) -Model 3007 170mm(approx)
|
|
PROVA-6800+6801 Power and Harmonics Analyzer (100A) |
|
Analysis for 3P4W, 3P3W, 1P2W, 1P3W True RMS Value(V 123 and L 123 ) Active Power(W, KW, MW, GW) Apparent and Reactive Power (KVA, KVAR) Power Factor (PF), Phase Angle (Φ) Energy (WH, KWH, KVARH, PFH) Current Measurement from 0.1mA to 3000A, Capable of Analyzing IT Standby Power Consumption to the Maximum Demand of a Factory Display of 35 Parameters in One Screen(3P4W) rogrammable CT (1 to 600) and PT (1 to 3000) Ratios Display of Overlapped Voltage and Current Waveform 2.4M Memory with Programmable Interval (1 to 6000 seconds, 17000 Records for 3P4W System) Output of Waveform, Power Parameters and Harmonics at Command Large Dot Matrix LCD Display with Backlight Average Demand (AD in W, KW, MW) aximum Demand (MD in W, KW, MW) with Programmable Period Harmonic Analysis to the 99th Order Display of 50 Harmonics in One Screen with Waveform Display of Waveform with Peak Values (1024 Samples/Period) Analysis of Total Harmonic Distortion (%THD-F) Graphic Phasor Diagram with 3 Phase System Parameters Capture 28 Transient Events (Time+Cycles) with Programmable Threshold(%) 3 Phase Voltage Unbalance Ratio (VUR) 3 Phase Voltage Unbalance Factor (d0%, d2%) Calculated Unbalance Current through Neutral Line (In) Optical isolated USB Interface Built-in Timer and Calendar for Data Logging onductor Size: -Model 6801 30mm(approx) -Model 6802 5 55mm(approx),64*24mm(bus bar) -Model 3007 170mm(approx
|
|
TES-3600 3P4W POWER ANALYZER |
|
10 Display Easy - to - View LCD Screen. Connectors for 4 Current Sensing Clamps. 1P2W, 1P3W, 3P3W2M & 3P4W Power Measurement. True RMS Sensing. Power KW, KVAR, KVA, PF, θ ,Hz, & Energy KWh, KVARh & KVAh Measurement. Phase sequency indicator function. Backlight display function. Manual Data Memory and Read (99 sets). Data Logging (512KB Memory, 20,000 sets) Programmable Trigger - Points and Start / Stop Time. RS-232 Optical Interface with three phase voltage / current Waveform display and Harmonic analysis. Easy - to - use Push - Button Operation. Light Weight, Portable Design.
|
|
TES-52 Sound Level Meter |
|
0.1dB Resolution Range from 30 to 130dB A&C frequency weighting Fast/Slow Dynamic characteristic Maximum with Elapsed time Manual data memory and read 5Selectable Ranges Bargraph Indication Logging Function (99 Sets)
|
|
TES-1359 Sound Level Meter |
|
0.1dB Resolution Range from 30 to 130dB Fast/Slow dynamic characteristic A&C Frequency Weighting IEC61672-1 : 2002 Class 2 IEC60651 : 1979 Type 2 ANSI S1.4 : 1983 Type 2
|
|
TES-1358 Sound Analyzer Real Time 1/1 & 1/3 Octave band Analysis |
|
TES-1358A (230V) TES-1358B (110V)
Real-time 1/1-Octave and 1/3-Octave analysis. Wide linearity range of 100dB. Large display with backlighting. Real time clock with calendar. Memory max. 10000 records of Lp data. RS-232 interface.
|
|
TES-1357 Sound Level Meter |
|
0.1dB Resolution Range from 30 to 130dB Fast/Slow dynamic characteristic A&C Frequency Weighting
|
|
TES-1354/TES-1355 Noise Dose Meter |
|
Measure % Noise Dose / Exposure Time / Sound Level Real time clock with calendar RS-232 interface
|
|
TES-1353 Integrating Sound Level Meter(RS-232) |
|
Wide linearity range of 100dB 32000 Records Data logging function RS-232 interface Real time clock with calendar
|
|
TES-1352A Programmable Sound Level Meter |
|
Auto ranging 0.1dB Resolution Range from 30 to 130dB A&C Frequency Weighting Fast/Slow dynamic characteristic 16000 Records Data logging function RS-232 interface Real time clock with calendar
|
|
TES-1351 Sound Level Meter |
|
0.1dB Resolution Maximum hold function AUX OUTPUT JACKS
|
|
TES-1350R Sound Level Meter(RS232) |
|
0.1dB Resolution Maximum hold function AUX OUTPUT JACKS RS232
|
|
TES-1350A Sound Level Meter |
|
0.1dB Resolution Maximum hold function AUX OUTPUT JACKS
|
|
TES-1326s/1327/1327K Infrared Thermometer |
|
0.1 ℃/0.2 ℉ Resolution -20 ℃ ~ 500℃ Built-in Laser Sighting/Backlight LCD display Memory / Read logging Capacity (50 Sets) (1327) Adjustable emissivity (1327) Audible and visible alarm (1327/1327K) MAX / MIN Reading Data memory and read function (1327/1327K) Emissivity adjustable (1327/1237K)
|
|
TES-1321A/TES-1322A Infrared/K-Type Thermometer |
|
0.1℃/0.2 ℉ Resolution Infrared: -20 ℃~500 ℃ Thermomuople input "K": -50 ℃ ~ 1370 ℃ Built-in Laser sighting / Backlight LCD display Data Memory and Read Capacity 20 sets. (TES-1322A) Adjustable & Visible Alarm MAX/MIN Reading
|
|
TES-1319A Thermometer |
|
Type "K" Thermocouple Input. Switchable Resolution 0.1° / 1 ° . With ℃& ℉ switching. Max / MIN Function. Data Hold Function. Flip-up stand.
|
|
TES-1317/TES-1318 Platinum RTD Thermometer |
|
Pt 3916/3926/385 RTD standard. 7500 DataLogging capacity. (1317) Warning beeper with HI/LO setting. Time setting. MAX / MIN with TIME, MAX-MIN AVG Hold function. ℃ / ℉ / K User-Selective. Back - Light LCD display. Dual input function T1/T2 temperature display. (1318)
|
|
TES-1315/TES-1316 K.J.E.T.R.S.N. Data-Logger Thermometer |
|
Highly accurate thermometer with thermocouple K, J, E, T, R, S, N type. Dual input function T1/T2 temperature display. (1316) 7500 DataLogging capacity. Warning beeper with HI/LO setting. MAX/MIN with TIME, MAX-MIN AVG, HOLD function. ℃ / ℉ / K User-Selective. Back-Light LCD display.
|
|
TES-13131/TES-1314 K.J.T.E.R.S.N. Thermometer |
|
Highly accurate thermometer with thermocouple K, J, E, T, R, S, N type. Dual input function T1/T2 temperature display. (1314) Warning beeper with HI/LO setting. MAX/MIN with TIME, MAX–MIN AVG, HOLD function. ℃ / ℉ / K User-Selective. Back-Light LCD display
|
|
TES-13131/TES-1314 K.J.T.E.R.S.N. Thermometer |
|
Highly accurate thermometer with thermocouple K, J, E, T, R, S, N type. Dual input function T1/T2 temperature display. (1314) Warning beeper with HI/LO setting. MAX/MIN with TIME, MAX–MIN AVG, HOLD function. ℃ / ℉ / K User-Selective. Back-Light LCD display
|
|
TES-1311A/TES-1312A Thermometer |
|
Type "K" Thermocouple Input Switchable Resolution 0.1° / 1° With℃& ℉ switching Max / MIN Function Data Hold Function Room Temperature Compensated T1 & T2 dual points display T1 - T2 differential measurement Flip-up stand Backlight LCD display
|
|
TES-1310/1320 Thermometer |
|
Switchable Resolution 0.1° /1.0 ° Single/Dual Channels with Differential Measurements Data Hold Function
|
|
TES-1307 Datalogging K/J Thermometer |
|
K/J Type thermocouple input Auto ranging Dual display LCD 8000 Record Data logging Capacity Maximum / Minimum / Average reading Relative reading RS-232 interface (software include)
|
|
TES-1306 Thermometer |
|
K/J Type thermocouple input Auto ranging Maximum / Minimum reading Relative reading Multi-channels scanner (T1-->T2-->T1 - T2)
|
|
TES-1304/TES-1305 Printing/Data-Logger Thermometer |
|
Type K. J. E. T. thermocouple input Dual channels with multi-functions (T1, T2 & T1-T2) Built-in thermo printer with programable time internal setting (1304) Data-logging capacity via RS-232 (1305)
|
|
TES-1300/TES-1302/TES-1303 Thermometer |
|
Max Hold Function Data Hold Function Aux output JACKS T1-T2 differential measurement
|
|
RM-1500/RM-1501 Digial Tachometer |
|
5 Digits LCD Display Light Reflex Measurement Range 10.00 to 99,999 RPM Measuring Distance 50 to 300mm Event counter with elapsed time RM-1502 optional Contact Adaptor Max / Min / Hold : True Average Auto Range RPM RS-232 Infterface for Model RM-1501 Contact RPM and circumferential velocity measurements in one simple adaptor(RM-1502)
|
|
RM-1000 Digital Optical Tachometer |
|
Direct Light-Beam Sensing Range: 10-100,000RPM Memory: Max, Min, 0
|
|
PROVA-8000 Programmable Power Supply |
|
Over-Voltage , Over-Current Protection Bulit-in Buzzer Alarm Easy RECALL and STORE functions Stby / Operate Button English-like RS-232C commands OCP With Programmable Timeter 200 Sets of Memory AUTO-STEP function with proggrammable interval Bi-direction RS-232C interface 3.8 kg / 8.4 Lbs weight
|
|
TES-6220 Digital Power Supply |
|
Two 3 1/2 LCD display volts and Amps simultaneously Multi-protections for overload, thermal, short circuit and reversing polarity Adjustable current limiting operation available Output Voltage: 0-60VDC Max. output Current: 3A
|
|
TES-6210 Digital Power Supply |
|
Output Voltage: 0-30VDC Max. output Current: 3A
|
|
TES-3096 DC/AC KW CLAMP METER |
|
Compact Size Trms KW measurement AC/DC Current Measurement (AC 600A/DC 600A) 600V AC & 600V DC,Ohm/Continuity Beeper 600 V AC & 600 V DC. Ohm/Coninuity Beeper One Touch DCA Zero
|
|
TES-3095T TRMS KW Clamp Meter |
|
3-3/4 Digital LCD, 4000 count, Autoranging. Trms KW, Current, Voltage measurement. AC Current 0.1A to 700A. Resistance and Continuity test. Data hold & MAX function. Pocket size. Auto Power off.
IEC1010-1 CAT III 600V
|
|
TES-3079K Power Clamp Meter |
|
HVAC Application:
Check current draw in motors and compressors. Use MAX/MIN/Rescording in the temperature mode to assess efficiency. Test run/start capacitors. Confirm low voltage control signals. Measure flame safeguard device current draw. Confirm power sources. Analyze temperature and voltage or current data with the aid of the time stamp. Insulation test up to 100M Ω. Electrical Application:
Check for energized circuits and balance loads. 1 Φ /3 Φ (3P3W/3P4W)Power analyzer. Evaluate electrical contacts. Capture motor in-rush current readings. Determine peak power demand periods. Verify line voltage stability. Monitor motors and other loads for excess heat. Check motor run/start capacitor values.
|
|
TES-3079K Power Clamp Meter |
|
HVAC Application:
Check current draw in motors and compressors. Use MAX/MIN/Rescording in the temperature mode to assess efficiency. Test run/start capacitors. Confirm low voltage control signals. Measure flame safeguard device current draw. Confirm power sources. Analyze temperature and voltage or current data with the aid of the time stamp. Insulation test up to 100M Ω. Electrical Application:
Check for energized circuits and balance loads. 1 Φ /3 Φ (3P3W/3P4W)Power analyzer. Evaluate electrical contacts. Capture motor in-rush current readings. Determine peak power demand periods. Verify line voltage stability. Monitor motors and other loads for excess heat. Check motor run/start capacitor values.
|
|
TES-3063/3064 Power AC/DC Clamp Meter |
|
RS-232 interface to talk with PC 4 digits with dual display LCD Amp / Voltage f requency measurement Dual display KW+PF , KVA+PF , V+A 4000 continuity point data logger , 25 point manual data logger True power / apparent power / power factor measurement True RMS. V , A , W , cap , lnd , phase indicator MIN / MAX measurement Peak hold detector Dual display A+Hz , V+Hz EN61010-1 600V Installation CAT III Pollution Degree 2
|
|
PROVA-6601 3 Φ PF Power Clamp |
|
PF( 3 Φ 3W , 3 Φ 4W 1Φ 2W ) AC+DC 2000A,600V Power Factot AC+DC 1200KW(1 Φ ) AC+DC 200KW(3Φ ) AC/DC Auto Detection Dual Display V+Hz, A+V,KW+PF,KVA+KVAR
|
|
PROVA-6600 3 Φ Power Clamp |
|
3 f 4W, 3 f 3W, 3 f Balanced, 1 f 2W, and 1 f 3W Power Measurement. AC+DC true power, and True RMS AC Voltage and Current AC+DC 2000A, AC 600V, DC 800V AC+DC 1200KW(1 f ), AC+DC 2000KW (3 f ) Dual Display V+Hz, A+Hz, W+PF, KVA+KVAR, V+A Phase Angle Measurement 3 f RST(L1L2L3) Sequence Indication. Memory of 4 records. DCA/DCW Auto Zero when power clamp powering on. AC/DC Auto Detection. Auto range.
|
|
PROVA-8500 Energy-Saving Tester |
|
Standby power measurement ( 0 to 100W width 0.001W resolution) Regular power(0~2000W) 100W AC power supply + AC power analyzer] Programmable nominal output (85V to 250V , 45Hz to 65Hz) power quality measurement(W , PF , V , A) PC programmable through RS-232C interface( Optional RS-232C to USB bridge) Programmable Over current protection(OCP) Memory of 99 preset voltage and frequency Standby and Operation Button Back space for easy correction Standby power measurment of note book, destop PC,LCD TV,...
|
|