TES-3600N 3P4W POWER ANALYZER |
 |
10 Display Easy - to - View LCD Screen. Connectors for 4 Current Sensing Clamps. 1P2W, 1P3W, 3P3W2M, 3P3W3M & 3P4W Power Measurement. True RMS Sensing. Power KW, KVAR, KVA, PF,θ,Hz, & Energy KWh, KVARh & KVAh Measurement. |
|
|
 |
- 10 Display Easy - to - View LCD Screen.
- Connectors for 4 Current Sensing Clamps.
- 1P2W, 1P3W, 3P3W2M, 3P3W3M & 3P4W Power Measurement.
- True RMS Sensing.
- Power KW, KVAR, KVA, PF,θ,Hz, &
Energy KWh, KVARh & KVAh Measurement. - Phase sequency indicator function.
- Backlight display function.
- Manual Data Memory and Read (50 sets).
- Data Logging
- USB Optical Interface with three phase voltage /
current Waveform display and Harmonic analysis. - Easy - to - use Push - Button Operation.
- Light Weight, Portable Design.
ELECTRICAL SPECIFICATIONS (23℃±5℃) : q Voltage Measurement (V) : Range | Resolution | Accuracy | Input impedance | Overload protection | Nominal power system frequency | 999.9V | 0.1V | ±(0.3%rdg±10dgts) (>10V) | 2MΩ | 1000Vrms | 45Hz ~ 66Hz |
q AC Current Trms Measurement (A) Autoranging : Range | Resolution | Accuracy(including current probe) | Current probe output | Overload protection | Nominal power system frequency | 999.9A | 0.1A | ±(0.5%rdg±15dgts) (>10A) | 0.35mV/A | 1000Arms | 45Hz ~ 66Hz |
q Active Power measurement P (KW) : Range | Resolution | Accuracy | 999.9KW | 0.1KW | ±1.0%rdg±20dgts |
q Apparent Power measurement S (KVA) : Range | Resolution | Accuracy | 999.9KVA | 0.1KVA | ±1.0%rdg±20dgts |
q Reactive Power measurement Q (KVAR) : Range | Resolution | Accuracy | 999.9KVAR | 0.1KVAR | ±1.0%rdg±20dgts |
q Power Factor measurement (COSØ) : Range | Resolution | Calculated Accuracy | -1 ~ +1 | 0.001 | ±10dgts |
q Phase angle measurement (Ø) : Range | Resolution | Calculated Accuracy | +180°~ 0°~ -180° | 0.1° | ±15dgts |
q Frequency measurement (Hz) : Range | Resolution | Accuracy | Measurement source | 60HZ | 0.1Hz | ±0.1%rdg±2dgts | Voltage U1 > 10V |
q Three Phase Sequency Detection : Input voltage range | Normal phase indication | Reverse phase indication | Measurement source | 3P > 10V | 
| 
| U1, U2 and U3 |
q Power Energy measurement (Wh, VAh, varh) : Range | Resolution | Active power accuracy | Timer interval | Timer Accuracy | 9.999K | 0.001K | Wh : ±1.0%rdg±20dgts VAh : ±1.0%rdg±20dgts varh : ±1.0%rdg±20dgts | 1 sec | ±50ppm (25℃, 77℉) | 99.99K | 0.01K | 999.9K | 0.1K | 9.999M | 0.001M | 30.59M | 0.01M |
q Harmonic measurement (use only PC on line analyzer) : Order | Accuracy | Harmonic Source | 1 ~ 63 | ±3%THD | U1, U2, U3 > 10V I1, I2, I3 > 10A |
q Waveform (use only PC on line displayed). Select Phase A, B or C. Select the Voltage and current waveform outputs. General Specifications : Size | 235(L)x116(W)x54(H)mm (9.3"Lx4.6"Wx2.1"H) | Operating Temperature and Humidity | 0℃to 40℃ (32℉ to 104℉) R.H. < 80% non-condensing | Storage Temperature and Humidity | -10℃to 60℃ (14℉to 140℉) R.H. < 70% non-condensing | Accessories | © Instruction manual © Software CD-ROM / Optical USB interface © Deluxe carrying case © Battery ( “AA” 1.5V x 8pcs ) © AC adaptor (110V→12V ; 220V→12V) © 4pcs current clamp transducer (1, 2, 3, 4 cable length 3 meters) (1000A AC, jaw opening 42mm) © 4pcs crocodiles test leads (blue, yellow, red, black, wire length 3 meters) |
|
|
LANGUAGUE |
|
| |