Search: Phone:86-21-33871640 86-21-51087628

Phone:
86-21-33871640
86-21-51087628

QQ
PRODUCTS
Multimeter
DC/AC Current Clamp Meter
Earth/Ground Tester
Calibrator
EMF Tester
Humidity/Temperature Meter
Insulation Tester
Lan Cable Tester
Battery Impedance Tester
CO2 Tester
Light Meter
Loop/PSC Tester
Anemometer
PH Tester
Power Analyzer
Power Clamp Meter
Power Supply/Inverter
Tachometer
Thermometer/Infrared Thermometer
Sound Level Meter
3 Phase Power Analyzer
Flexible AC Current Clamp
Printer
Solar Power Meter
Milli-Ohmmeter
Luminous Flux Meter
Color Meter
AFLEX-3003 Flexible VA Harmonics Tester
Power Analysis(3005)

W, KW, H.P.
VA ,KVA, VAR, KVAR
PF, Phase Angle( Φ )
Energy (WH, KWH)
Dual displays (W+PF, VA+KVAR)
Balanced 3 Φ Power Quality and Swquence
Harmonics Analysis

True RMS( V and A)
3000 A
Non-interrupted Harmonic Analysis ( V and A ) to the 50th Order in % and Magnitude
Analysis of % THD-F and C.F.
Fast Peak Function (33μs and 39μs)
Programmable PT (1 to 250 )ratios
Auto - Power - Off:30 Minutes

Flexible probe , different from normal clamp meter, can pass through obstacles at will and wind many conducting wires simultaneously, max. diameter 170mm

AC Watt (50 or 65 Hz, PF 0.5 to 1, CT=1) AFLEX-3005 only

Range
Resolution
Accuray of reading
100.0 - 999.9 W
0.1 W
2% of range
1.000 - 9.999 KW
0.001 KW
2% of range
10.00 - 99.99 KW
0.01 KW
2% of range
100.0 - 999.9 KW
0.1 KW
2% of range
1000 - 9999 KW
1 KW
2% of range

AC Voltage(50 or 65 Hz, ,Auto Rang,True RMS)

Range
Resolution
Accuray of reading
4.0 V - 600 V
0.1 V
±0.5% ± 5dgts

Harmonics of AC Current in % and Magnitude(1 to 50th order)

Range
Resolution
Accuray in %
Accuray of Magnitude
1-20th
0.1%
±2%
±2% of reading ±0.4A
21th-50th
0.1%
±4% of reading ±2.0%
±4% of reading ± 0.4V

AC Current(50 or 65 Hz ,Auto Rang,True RMS)

Range
Resolution
Accuray of reading
0 - 300.0 A
0.1 A
1% of range
300.0 - 999.9 A
0.1 A
1% of range
1000 - 3000 A
1 A
1% of range

Harmonics of AC Voltage in % and Magnitude(1 to 50th order)

Range
Resolution
Accuray in %
Accuray of Magnitude
1-20th
0.1%
±2%
±2% ±0.5V
21th-50th
0.1%
±4% of reading ±2.0%
±4% of reading ± 0.5V

Total Harmonics Distortion(%THD-F,1 to 50th order)

Range
Resolution
Accuray of reading
0.0-20%
0.1%
±2%
20-100%
0.1%
±6% of reading ±1%
100-999.9%
0.1%
±10% of reading ±1%
LANGUAGUE
Home | About us | Sitemap | Products | Contact Us

TES Electrical Electronic Corp.
86-21-33871640 86-21-51087628