Search: Phone:86-21-51087628 WeChat:13482459793

PRODUCTS
EMF Tester
Thermometer
Infrared Thermometer
Sound Level Meter
Humidity/Temperature Meter
Light Meter
Anemometer
Multimeter
DC/AC Current Clamp Meter
Earth/Ground Tester
Calibrator
Insulation Tester
Lan Cable Tester
Battery Impedance Tester
CO2 Tester
Loop/PSC Tester
PH Tester
Power Analyzer
Power Clamp Meter
Power Supply/Inverter
Tachometer
3 Phase Power Analyzer
Flexible AC Current Clamp
Printer
Solar Power Meter
Milli-Ohmmeter
Luminous Flux Meter
Color Meter
PROVA-6830A+3007S (3000A)Power and Harmonics Analyzer
Power Analysis for 3P4W, 3P3W, 1P2W, 1P3W
True RMS value (V123 and I123)
Active Power (W, KW, MW, GW)
Apparent and Reactive Power (KVA, KVAR)
Power Factor (PF), Phase Angle (Φ)
Energy (WH, KWH, KVARH, PFH)
AC Current (10A to 3000A) and Voltage measurement: True RMS, Auto Range.

PROVA-6830A + 3007 (3000A) 

 Electrical Specifications: (23±5) 

AC Watt 

Range
(0 to 3000A)
Resolution
Accuracy of Readings
> 20 V and > 30A
< 20V or < 30A
10.0 – 999.9 W
0.1W
 
 
±1% of range
 
 
±2% of range
1.000 – 9.999 KW
0.001 KW
10.00 – 99.99 KW
0.01 KW
100.0 – 999.9 KW
0.1 KW
1000 – 9999 KW
1 KW

 

Range of CT (Current Transformer) Ratio: 1 to 600 

AC Apparent Power (VA, from 0.000 VA to 9999 KVA):  VA = V r.m.s. x A r.m.s 

AC Reactive Power (VAR, from 0.000 VAR to 9999 KVAR):  VAR = (VA2 –  W2) 

AC Active Energy (mWH, WH, or KWH, from 0mWH to 999,999KWH): WH = W * Time (in hours)

 

AC Current  (Auto range, TRMS, Overload Protection AC 3000A) 

Range
Resolution
Accuracy of Readings
10.0 – 300.0A
0.01A / 0.1A
±1% of range
300.0 – 3000A
0.1A / 1A

AC Voltage  (Auto range, TRMS, Overload Protection AC 800V) 

Range
Resolution
Accuracy of Readings
20.0 V – 500.0 V (Phase to Neutral)
0.1 V
±0.5% ± 5dgts
20.0 V – 600.0 V (Phase to Phase)

 Range of VT (Voltage Transformer) Ratio: 1 to 3000 

Harmonics of AC Voltage in Percentage 

Range
Resolution
Accuracy
1 – 20th
 
0.1%
±2%
21 – 49th
±4% of reading ± 2.0%
50 – 99th
±6% of reading ± 2.0%

 Harmonics of AC Voltage in Magnitude 

Range
Resolution
Accuracy
1 – 20th
 
0.1V
±2% ± 0.5V
21 – 49th
±4% of reading ± 0.5V
50 – 99th
±6% of reading ± 0.5V

 Peak Value of ACV (peak value > 20V) or ACA (peak value > 30A), VT=1 

Range
Sampling Time
Accuracy of Reading
50 Hz
19μs
± 5% ± 30 digits
60 Hz
16μs

 Crest Factor (C.F.) of ACV (peak value >20V) or ACA (peak value > 30A), VT=1

Range
Resolution
Accuracy of Readings
1.00 – 99.99
0.01
± 5% ± 30 digits

 Harmonics of AC Current in Percentage 

Range
Resolution
Accuracy
1 – 20th
 
0.1%
±2%
21 – 50th
±6%
51 – 99th
±10%

 Harmonics of AC Current in Magnitude 

(1 to 99th order, min. current at the 50 or 60 Hz, True RMS < 300A) 

Range (0 – 300A)
Resolution
Accuracy
1 – 20th
 
0.1%
±2% of reading ± 4A
21 – 50th
±4% of reading ± 4A
51 – 99th
±6% of reading ± 4A

(1 to 99th order, min. current at the 50 or 60 Hz, 3000A > True RMS > 300A) 

Range (300–3000A)
Resolution
Accuracy
1 – 20th
 
0.1%
±2% of reading ± 40A
21 – 50th
±4% of reading ± 40A
51 – 99th
±6% of reading ± 40A

 Power Factor  (PF) 

RangeResolutionAccuracy
> 20V and > 30A< 20V or < 30A
0.000 – 1.0000.001± 0.04±0.1

 Phase Angle  (Φ, V > 20V, A > 30A) 

Range
Resolution
Accuracy
-180° to 180°
0.1°
± 2°
0° to 360°

 Frequency of ACV (RMS value > 10V) or ACA (RMS value > 30A) 

Range
Resolution
Accuracy
45 – 65 Hz
0.1 Hz
± 0.2Hz

 Total Harmonic Distortion  (THD-F) 

Range
Resolution
Accuracy
0.0 – 20%
 
0.1%
± 2%
20 – 100%
± 6% of reading ± 5%
100 – 999.9 %
± 10% of reading ± 10%


 General Specifications: Indoors Use  

PROVA 6830A Analyzer 

Battery Type:
1.5V SUM-3 x 8
External DC Input:      
Use only power supply adapter Model PHAPSA
Display:
Dot Matrix LCD (240x128) with backlight
LCD Update Rate:
1 time / second
Power Consumption:
140mA (approx.)
No. Of Samples:
1024 samples / period
Data Logging Files:
85
Max. File Capacity:
17474 records (3P4W, 3P3W)
26210 records (1P3W)
52420 records (1P2W)
4096 records (50 Harmonics / record)
Sampling Time:
2 to 3000 seconds for data logging
Low battery Indication:   
Overload Indication:
OL
Operating Temperature:
-10°C to 50°C
Operating Humidity:
less than 85% relative
Storage Temperature:    
-20°C to 60°C
Storage Humidity:
less than 75% relative
Dimension:
257 (L) x 155 (W) x 57 (H) mm
10.1” (L) x 6.1” (W) x 2.3” (H)
Weight:                       
1160g (Batteries included)
Accessories:               
Probes (model 3007) x 3
Test leads (3 meter long) x 4
Alligator clips x 4, Carrying bag x 1
Users manual x 1, Batteries 1.5V x 8
AC power adapter x 1, Software CD x 1
Software users manual x 1
USB to RS232 cable x 1

 

AFLEX 3007S Flexible Current Probes 

Probe Length:            ( 3007-24)
24 in / 610 mm
Minimum Bending Diameter:  
35mm
Connector Diameter:  
23mm
Cable Diameter:
14mm
Cable Length from Probe to Box:   
1700mm
Cable Length from Box to Output: 
1700mm
Range Selection:        
Manual (300A, 3000A)
Battery:                           
powered by power analyzer
Dimension (Box):       
130mm(L) x 80mm(W)x 43mm(H)
5.1”(L) x 3.1”(W) x 1.7”(H)
Weight:                           
410g

LANGUAGUE
Home | About us | Sitemap | Products | Contact Us

Shanghai Zhongxuan Electronics Co.,Ltd.
TEL:86-21-51087628
WeChat:13482459793