3-3/4 Digital LCD, 4000 count, Autoranging. Trms KW, Current, Voltage measurement. AC Current 0.1A to 700A. Resistance and Continuity test. Data hold & MAX function. Pocket size. Auto Power off.
IEC1010-1 CAT III 600V
AC KW (Trms) (Autorange)
Range
Resolution
Accuracy
Frequency Range
Overload protection
40.00KW
0.01KW
±( 5% + 30) PF>0.5
50, 60Hz
420KW
250.0KW
0.1KW
AC Current (Trms) (Autorange)
Range
Resolution
Accuracy
Frequency Range
Overload protection
400A
0.1A
±( 1% + 10)
50, 60Hz
800Arms
700A
1A
AC Voltage (Trms) (Autorange)
Range
Resolution
Accuracy
Frequency Range
Input Impedance
Overload protection
400V
0.1V
±( 1% + 10)
50~1KHz
1MΩ
600Vrms
600V
1V
Resistance (Autorange)
Range
Resolution
Accuracy
Overload protection
400Ω
100mΩ
±( 1% +3)
600Vrms
4000Ω
1Ω
Continuity Beeper
Range
Sound Level
Max Open Circuit Voltage
Overload protection
≦38Ω
3.3V
600Vrms
GENERAL SPECIFICATIONS
Numerical Display
3-3/4 digit liquid crystal display (LCD) maximum reading 3999.
Over Range Indication
LCD will show an" ".
Low Battery Indication
The is displayed when the battery voltage drops below the operating voltage
Power Source
One 9V battery (006P or IEC6F22)
Battery Life
100hr approx.
Operating Temperature and Humidity
0℃ to 50℃ (32℉ to 122℉) below 80﹪RH.
Storage Temperatur and Humidity
-10℃ to 60℃ (14℉ to 140℉) below 70﹪RH
Dimensions
192(L) x 64(W) x 31(H)㎜
Weight
Approx. 240 g
Jaw Opening Diameter
Cables 27 mm
Accessories
Carrying case, Battery & Instruction Manual, Test Lead.