Search: Phone:86-21-51087628 WeChat:13482459793

PRODUCTS
EMF Tester
Thermometer
Infrared Thermometer
Sound Level Meter
Humidity/Temperature Meter
Light Meter
Anemometer
CO Meter/ NDIR CO2 Meter
Particle Counter
PH Tester
Vibration Meter
Color Meter
3 Phase Power Analyzer
Multimeter
DC/AC Current Clamp Meter
Earth/Ground Tester
Calibrator
Insulation Tester
Lan Cable Tester
Battery Impedance Tester
Loop/PSC Tester
Power Analyzer
Power Clamp Meter
Power Supply/Inverter
Tachometer
Flexible AC Current Clamp
Printer
Solar Power Meter
Milli-Ohmmeter
Luminous Flux Meter
TES-3910 Trms Clamp Meter (DC/AC 1000A)
Capacitance measurement 1000µF
Variable-frequency drive (VFD) V & Hz measurement.
Lo-Z voltage measurement to drain ghost voltages.
Check 3Φ phase sequence.
True RMS reading on AC and DC+AC mode.
Inrush current measurement.
A measurement for HVAC flame sensors.
mV measurement range to interface with other accessories.
Crest Factor & Harmonic ratio measurement.
Data hold, Auto hold & Peak hold mode.
Max/Min/Avg record mode.
Data memory & read function.

ELECTRICAL SPECIFICATIONS (23±5)

 

AC Current (40Hz to 400Hz) : VFD Trms

 

RangeResolutionAccuracySensitivityOverload Protection
99.99A10mA±2%±20dgts (50, 60Hz) ±4%±20dgts (40~400Hz)>0.25A1000A AC
999.9A100mA>2.5A

 

DC Current :

 

RangeResolutionAccuracySensitivityOverload Protection
99.99A10mA±2% ±20dgts>0.25A1000A
999.9A100mA>2.5A

 

ACA Inrush Current : VFD Trms

 

RangeResolutionSensitivityMeasurement TimeOverload Protection
99.99A0.01A>5A100mS1000AAC

 

DCμA : (Burden Voltage : 3.6mV/µA)

 

RangeResolutionAccuracySensitivityOverload Protection
99.99μA10nA±1±20dgts>0.30µA1000V
999.9μA100nA>3.0µA

 

ACmA : VFD Trms (Burden Voltage : 3.6mV/µA)

 

RangeResolutionAccuracySensitivityOverload Protection
99.99mA10nA±1%±10dgts (50, 60Hz) ±2%±10dgts (40~400Hz)>0.30µA1000V
999.9mA100nA>3.0µA

 

AC Voltage (40Hz to 400Hz) : VFD Trms

 

RangeResolutionAccuracySensitivityOverload Protection
999.9mV0.1mV±1%±10dgts (50, 60Hz) ±2%±10dgts (40~400Hz) 40 ~ 300Hz on mV range>2mV1000V (LoZ: 600V 1 minute)
9.999V1mV>20mV
99.99V10mV>200mV
999.9V  100mV>2V

 

DC Voltage

 

RangeResolutionAccuracySensitivityOverload Protection
999.9mV0.1mV±1% ±10dgts>2mV1000V (LoZ: 600V 1 minute)
9.999V1mV>20mV
99.99V10mV>200mV
999.9V  100mV>2V

 

Resistance (Continuity<40Ω on the range) :

 

RangeResolutionAccuracyOverload Protection
999.9Ω100mΩ±1% ±10dgts1000V
9.999KΩ1Ω
99.99KΩ10Ω
999.9KΩ100Ω

 

 Phase sequence indication :

 

RangeFrequency ResponseOverload Protection
80V to 480V50Hz / 60Hz1000V

 

Diode (Continuity<40mV) :

 

RangeResolutionAccuracyOverload Protection
3.000V1mV±1±10dgt1000V

 

Frequency :

 

RangeResolutionAccuracySensitivity
40Hz/1KHz0.1Hz±0.5%rdg ±2dgts       V > 5% range          μA, A > 30%

 

Capacitance:

 

RangeResolutionAccuracyOverload Protection
1.000μF1nF±1.5%±5dgts1000V
10.00μF10nF
100.0μF100nF
1000μFF

GENERAL SPECIFICATIONS :

 

Accessories Instruction Manual, Battery, Carrying case & Test Lead

 

Weight/Size : 236(L)x80(W)x39(T)mm/332g

 

Max Wire Diameter : 33mm

 

Category : CAT III 1000V, CAT IV 600V

LANGUAGUE
Home | About us | Sitemap | Products | Contact Us

Shanghai Zhongxuan Electronics Co.,Ltd.
TEL:86-21-51087628
WeChat:13482459793