DC Current (Autorange & Manual) |
Range |
Resolution |
Accuracy |
Overload Protection |
400A |
0.1A |
+/-1.5%+/-3dgts |
3000A |
2500A |
1A |
+/-1.5%+/-3dgts |
3000A | |
ANALOG OUTPUT (Autorange & Manual ) |
Range |
OUTPUT |
Accuracy |
Overload Protection |
400A |
1mV/A |
+/-2.5%+/-0.5A |
600V AC |
2500A |
1mV/A |
+/-2.5%+/-5A |
600V AC | |
AC Current (Autorange & Manual, True RMS) |
Range |
Resolution |
Accuracy |
Overload Protection |
|
|
50/60Hz |
40-400Hz |
3000A |
400A |
0.1A |
+/-1.5%+/-5dgts |
+/-2.0%+/-5dgts |
3000A |
2100A(0-1000) |
1A |
+/-2.0%+/-5dgts |
+/-2.5%+/-5dgts |
3000A |
2100A(1000-2100) |
1A |
+/-2.5%+/-5dgts |
+/-3.0%+/-5dgts |
3000A | |
ANALOG OUTPUT (Autorange & Manual) |
Range |
OUTPUT |
Accuracy |
Overload Protection |
400A |
1mV/A |
+/-2.5%+/-0.5A |
600V AC |
2100A |
1mV/A |
+/-2.5%+/-5A |
600V AC | |
DC Voltage (Autorange & Manual, Overload Protection 800VAC for all Range) |
Range |
Resolution |
Accuracy |
Input Impedance |
400mV |
0.1mV |
+/-1.5%+/-3dgts |
10MΩ |
4V |
0.001V |
+/-1.5%+/-3dgts |
5M Ω |
40V |
0.01V |
+/-1.5%+/-3dgts |
5MΩ |
400V |
0.1V |
+/-1.5%+/-3dgts |
5M Ω |
600V |
1V |
+/-1.5%+/-3dgts |
5M Ω | |
AC Voltage (Autorange & Manual ,True RMS, Input Impedance 5M W for all Range ) |
Range |
Resolution |
Accuracy |
Overload Protection |
4V |
0.001V |
+/-1.5%+/-5dgts |
800VAC |
40V |
0.01V |
+/-1.5%+/-5dgts |
800VAC |
400V |
0.1V |
+/-1.5%+/-5dgts |
800VAC |
600V |
1V |
+/-1.5%+/-5dgts |
800VAC | |
Range |
Continuity Beeper |
Open Circuit Voltage |
Overload Protection |
400 W |
<=40 W (approx) |
<=0.5V |
600VAC | |
TEMP K TYPE ℃ (Autorange & Manual) |
Range |
Resolution |
Accuracy |
Overload Protection |
-40~0 ℃ |
0.1 ℃ |
+/-2.0%+2 ℃ |
600VAC |
-0~400 ℃ |
0.1 ℃ |
+/-0.5%+1 ℃ |
600VAC |
400 ~1000 ℃ |
1 ℃ |
+/-0.8%+1 ℃ |
600VAC | |
AC+DC 250V POWER (Autorange & Manual) |
Range |
Resolution |
Accuracy |
Overload Protection |
40KW |
0.01KW |
+/-2.5%+/-5dgts |
800VAC 3000A |
400KW |
0.1KW |
+/-2.5%+/-5dgts |
800VAC 3000A | |
AC+DC 600V POWER (Autorange & Manual) |
Range |
Resolution |
Accuracy |
Overload Protection |
400KW |
0.1KW |
+/-2.5%+/-5dgts |
800VAC 3000A |
1200KW |
1KW |
+/-2.5%+/-5dgts |
800VAC 3000A | |
Jaw Opening |
Cable F 55mm Bus Bar 65mm(D) x 24mm(W) |
Power Source |
One 006P 9V or IEC 6F22or NEDA 1604 Battery |
Operating Temperature |
0 ℃ ~ 40 ℃ ( 32 ℉ ~104 ℉ ) |
Operating Humidity |
Less than 80% RH |
Dimensions |
10.7"(L) x 4.4"(W) x 18"(H) 271mm(L) x 112mm(W) x 26.2mm(H) |
Weight |
647g / 22.8oz. (Battery included) | |