ELECTRICAL SPECIFICATIONS : Accuracies are ±(...% of reading + ...digits) at 23℃±5℃,below 80% RH. q DC Voltage Range | Resolution | Accuracy | Input Impedance | Overload Protection | 200mV | 0.1mV | 0.5%+1 | 10MΩ | 600Vrms | 2V | 1mV | 1100Vrms | 20V | 10mV | 200V | 100mV | 1000V | 1V | 0.5%+2 |
q AC Voltage ( 50Hz to 500Hz ) Range | Resolution | Accuracy | Input Impedance | Overload Protection | 200mV | 0.1mV | 1%+5 | 10MΩ | 600Vrms | 2V | 1mV | 750Vrms | 20V | 10mV | 200V | 100mV | 750V | 1V | 1.2%+5 |
q DC Current Range | Resolution | Accuracy | Burden Voltage | Overload Protection | 200μA | 0.1μA | 1%+1 | 0.35V | 0.5A / 250V Fast Blow Fuse & Diode | 2mA | 1μA | 20mA | 10μA | 200mA | 100μA | 20A | 10mA | 1.2%+3 | 0.8V | 20A / 380V Fast Blow Fuse 20A for 30sec max. 10A continuity |
q AC Current ( 50Hz to 500Hz ) Range | Resolution | Accuracy | Burden Voltage | Overload Protection | 200μA | 0.1μA | 1.2%+3 | 0.35V | 0.5A / 250V Fast Blow Fuse & Diode | 2mA | 1μA | 20mA | 10μA | 200mA | 100μA | 20A | 10mA | 1.5%+5 | 0.8V | 20A / 380V Fast Blow Fuse 20A for 30sec max. 10A continuity |
q Resistance (Ω ) Range | Resolution | Accuracy | Max. Open Circuit Voltage | Overload Protection | 200Ω | 0.1Ω | 0.8%+2 | 3.2V | 600Vrms | 2KΩ | 1Ω | 0.5V | 20KΩ | 10Ω | 200KΩ | 100Ω | 2MΩ | 1KΩ | 20MΩ | 10KΩ | 1.5%+3 |
q Diode ( ) Range | Resolution | Accuracy | Max. Open Circuit Voltage | Max. Test Current | Overload Protection | 
| 1mV | 2%+ 2 | 3.2V | 1.0mA | 600Vrms |
q Continuity ( ) Range | Continuity Threshold | Max. Open Circuit Voltage | Overload Protection | 
| Continuity audible tone for tested resistance below 30Ω | 3.2V | 600Vrms |
q Frequency ( Hz ) ( Test Range 10Hz - 10MHz Auto Range ) Range | Resolution | Accuracy | Sensitivity | Overload Protection | 2KHz | 1Hz | 0.5%+2 | 1.5Vrms | 600Vrms | 20KHz | 10Hz | 200KHz | 100Hz | 2MHz | 1KHz | 10MHz | 10KHz | 3Vrms |
q Temperature Probe used : K (CA) type sensor Range | Resolution | Accuracy | °C | 0.1/1°C | 0°C~ 200°C ±(0.5%+1.5°C ) -50°C~ 0°C ±( 1% + 2°C ) 200°C~ 1300°C ±( 1% + 2°C ) | °F | 0.1/1°F | 32°F~ 200°F ±(0.5% + 3°F ) -58°F~ 32°F ±( 1% + 5°F) 200°F~ 1999°F ±( 1% + 4°F ) |
q Capacitance (F) Range | Resolution | Accuracy | Test Frequency | 2000pF | 1pF | 3%+10 | 400Hz | 200nF | 100pF | 2μF | 1nF | 20μF | 10nF |
Display: 3 1/2 Digital LCD Display Maximum Reading 1999. Sampling Rate: 2.5 readings per second Operating/Storage Condition: 0°C to 40°C<80% R.H. -10°C to 60°C<70% R.H. Power Source: one 9V Battery Battery Life Approx. 60hours (Alkaline Battery) 9V Power adaptor jack for long time application Size & Weight: 180(L)×82(W)×38(H)mm & 365g Accessories: Test leads ( pair), Spare fuse (0.5A/ 250V ), Battery, Instruction manual, Software, RS-232 Cable, “K” type thermocouple (TP-K01). |